Pharmaceutical glass machinery / Jianhu, Jiangsu, China jsjixiec@163.com

MACHINERY & EQUIPMENT / AUTOMATIC INSPECTION

Automatic glass container inspection

MANUFACTURED IN JIANHU, CHINA

Camera-based dimensional and visible-defect inspection for compatible empty glass containers.

Computer-vision inspection for empty pharmaceutical glass containers before box packing. Compatible transparent and amber glass vials can be reviewed, alongside ampoule applications. Camera configuration and inspection criteria are confirmed against your samples.

Application
Empty pharmaceutical glass
Review basis
Geometry & defect criteria
  • Measure overall container height, mouth outside diameter and body outside diameter.
  • Inspect the body, shoulder, neck, mouth and base for specified visible defects.
  • Screen for cracks, chips, glass particles, bubbles, streaks, spots and black marks.
  • Review malformed containers, missing or sloping bases, damaged mouths and tilted necks.
  • Agree sample-based detection limits, rejection criteria and handling requirements.

Send sample containers, drawings, target output and defect examples. Detection limits and acceptance criteria require application-specific review.

Request a quotation
jsjixiec@163.com

Technical & commercial reference

Specifications & budget

CHINA DOMESTIC SALES REFERENCECNY 170,000-205,000Per vial inspection machine

Vial vision inspection machine. Budget reference in Chinese yuan; not a binding export offer. Confirm configuration, taxes, packing, freight, installation and training in your written quotation.

RELATED TECHNICAL RESOURCES

Design studies & patent records

ON THE PRODUCTION FLOOR

Equipment in operation

Ampoule inspection / 0:14

A close view of ampoules passing through an inspection station.

Equipment selection questions

Does it inspect filled medicine containers?

The documented application is empty pharmaceutical glass containers before packing. Filled-product inspection, sterile processing and pharmaceutical validation are separate requirements and are not established by the displayed equipment information.

Can it detect every crack or cosmetic defect?

Detection depends on the sample, glass color, lighting, camera configuration and agreed defect limits. Supply accepted and rejected samples and define the defect list, minimum relevant size, target speed and rejection criteria for a technical trial.